High Precision Electrical Resistance Probe Corrosion Monitoring System
Products list- High Precision Electrical Resistance Probe Corrosion Monitoring System
- LPR Probe corrosion monitoring system
- Two inch access fitting assembly
- Coupon corrosion monitoring system
- Integrated online corrosion monitoring system
- Retrievers & Service valves
- Corrosion and protection management system
- Automatic cleaning and maintaining system for pH electrode
- Automatic control of injection system for overhead
- Online High Temperature Ultrasonic Thickness Measurement system
- Online Electric Field Matrix Thickness Measurement system
- Portable corrosion monitoring instruments
As a sensing unit of inductance (high precision ER) corrosion monitoring system, inductance probes (high precision ER probe) provide you with various probes applicable to various temperatures, pressure, assembling and dissembling requirements according to various on-site environments.
General parameters
·Applicable temperature: ≤240℃(low temperature);≤430℃(high temperature)
·Applicable pressure: ≤2MPa (low pressure);≤30MPa (high pressure)
·Thickness of measuring sample: 0.25mm~1.0mm
·Shape of sample: Cylindrical /Flush
·Safe life of probe: ≤4years
·Useful life of probe: Sample thickness/annual corrosion rate = useful life
·Installing methods: stuffing box/ flange/ access fitting
Inductance probe with dual heads
Self-compensatory precision inductance probe with dual head was developed to monitor the pipeline corrosion. In the meanwhile, it also divided the tool for field technology evaluation and material choice.
Flush inductance probe
Sheet inductance probe: the occupancy of vertical space is small. It is suitable for small diameter pipeline. Because the measurement element is isolated with the probe body through the stuff material, it is anti-interference. The probe is installed which is parallel with the pipeline, so it can simulate the corrosion conditions exactly.
Cylindrical inductance probe
Cylindrical inductance probe: widely used. According to the different technology conditions, choose the different material, length and dismounting methods.
series | keywords | ||||||||||
temperature | Retractable | shape | retrievable | head numbers |
Temperature measurement |
||||||
Low | High | Yes | No | Cylindrical | Flush | Yes | No | One | Two | yes | |
ZK9251HT | ● | ● | ● | ● | ● | ● | |||||
ZK9200 | ● | ● | ● | ● | ● | ● | |||||
ZK9200HT | ● | ● | ● | ● | ● | ● | |||||
ZK9210 | ● | ● | ● | ● | ● | ● | |||||
ZK9201 | ● | ● | ● | ● | ● | ● | |||||
ZK9201HT | ● | ● | ● | ● | ● | ● | |||||
ZK9202-air cooler | ● | ● | ● | ● | ● |